492 entries, 81~96 shown
Card View
| Category Name | Manufacturer Name | Model Type | Year | Main Specifications | Location | Owner | ||
|---|---|---|---|---|---|---|---|---|
|
|
Generator/Transformer | 新ダイワ | DGM80BMK | Unknown |
This multi-purpose generator can output three-phase and single-phase three-wire power simultaneously without switching. It can be used not only for normal on-site use but also as an emergency power source for stores, offices, and facilities. It produces high-quality electricity that can be used for electronic devices such as air conditioners and computers. It also features an eco-mode function with a digital remaining capacity that lets you see the available power at a glance, and an oil guard. It also has a ground fault protection device. It has only been used for about 20 minutes and is in like-new condition. It is mounted on a stand with casters. Rated generator voltage (V): Three-phase 200/220, Single-phase three-wire 100/110, 200/220 Rated generator output (kVA): Three-phase four-wire 7/8, Single-phase three-wire 4.5/5 Generator frequency (Hz): 50/60 Rated generator current (A) Three-phase four-wire 20.2/21, Single-phase three-wire 22.5 x 2/22.7 x 2, 22.5/22.7 Fuel used: Diesel fuel Tank capacity (L): 36 Dimensions (length x width x height) (mm): 1095 x 640 x 895 Dry mass of main unit (kg): 335 Noise level {dB(A)/7m}: 61 (50Hz), 63 (60Hz)
|
Osaka Prefecture |
Sinko Shoukai Ltd.
|
Details |
|
|
Chiller/Cooling Tower | オリオン | RKE750C-VRA-G2 | 2023 |
This inverter chiller is like new and has only been used for a test run. It is still on the original pallet and includes the original box. The retail price is ¥1,001,000 (tax included). It uses non-fluorocarbon refrigerant R1234yf (HFO), significantly reducing environmental impact and eliminating the need for fluorocarbon management. Three inverters provide high precision and energy savings. Specifications: Cooling capacity: 3.3 kW, Flow rate range: 10-30 L/min, Chilled water pressure: 0.05-0.3 MPa, Ambient temperature range: -5 to 45°C, Liquid temperature range: 5 to 40°C, Power supply: Three-phase 200V, Power consumption: 1.6 kW, Dimensions: 398 x 695 x 940 mm, Weight: 85 kg.
|
Osaka Prefecture |
Sinko Shoukai Ltd.
|
Details |
|
|
air conditioner | DAIKIN INDUSTRIES | ERK10MV | Unknown | Osaka Prefecture |
Kei-Machine Co.,Ltd.
|
Details | |
|
|
air conditioner | DAIKIN INDUSTRIES | ERK15MV | Unknown | Osaka Prefecture |
Kei-Machine Co.,Ltd.
|
Details | |
|
|
Cleaning equipment and others | ニッコー | NW02-55M | 2013 |
Three-phase 200V Work weight 5kg Basket dimensions 600mm (without basket) Spray pressure 0.4MPa Body dimensions 1200 x 1600 x h1500mm Body weight 200kg The photo shows the machine in an uncleaned state.
|
Gunma |
Kobayashi Kikai Co.,Ltd.
|
Details |
|
|
air conditioner | DAIKIN INDUSTRIES | SUAS3MBU |
Three-phase 200V 50/60Hz Cooling capacity 5100/5700kcal/h Dimensions: W500 x D600 x H1300mm 92kg The photo shows the unit in an uncleaned condition.
|
Gunma |
Kobayashi Kikai Co.,Ltd.
|
Details | |
|
|
air conditioner | ハイアールジャパン | JA-SPH25B |
Single phase 100V Cooling capacity 2.2/2.5kw Operating current 10.5/10.2A The photo shows a representative product.
|
Gunma |
Kobayashi Kikai Co.,Ltd.
|
Details | |
|
|
Compressor | MEIJI AIR COMPRESSOR MFG | 2002 |
Capacity 390L Maximum operating pressure 1.08MPa Water pressure test pressure 1.62Mpa
|
Gunma |
Kobayashi Kikai Co.,Ltd.
|
Details | |
|
|
Compressor | ANEST IWATA | SAT-1000B-80 | 1993 |
Capacity: 1000L Maximum operating pressure: 9.0kgf/cm2 Water pressure test pressure: 13.5kgf/cm2 The photo shows the product in an uncleaned condition.
|
Gunma |
Kobayashi Kikai Co.,Ltd.
|
Details |
|
|
Cleaning equipment and others | ニッコー | NW02-55M | 2008 |
Three-phase 200V Work weight 5kg Basket dimensions 600mm Spray pressure 0.4MPa Body dimensions 1200 x 1600 x h1500mm Body weight 200kg The photo shows the uncleaned state. Oil skimmer switch broken (usable) Weekly timer cannot be used
|
Gunma |
Kobayashi Kikai Co.,Ltd.
|
Details |
|
|
Mist Collector | AKAMATU DENKI | HVS-100-056 | Unknown |
★
|
Ibaraki Prefecture, |
TokyoEngineering
|
Details |
|
|
Chiller/Cooling Tower | DISCO | DTU162 | 2004 |
★
|
Ibaraki Prefecture, |
TokyoEngineering
|
Details |
|
|
Compressor | ANEST IWATA | EFBS07 | Unknown | Osaka |
Kei-Machine Co.,Ltd.
|
Details | |
|
|
Compressor | HITACHI | POD-0.75LES |
1 horsepower (0.75kw/0.9kw) Single phase 100v 50/60Hz Oil-free type With dryer Operating time 1722Hr
|
Gunma |
Kobayashi Kikai Co.,Ltd.
|
Details | |
|
|
Dust Collector | HITACHI | G-751 |
Three-phase 200V 1 horsepower (0.75kw) 50Hz The photo shows the unit in an uncleaned condition.
|
Gunma |
Kobayashi Kikai Co.,Ltd.
|
Details | |
|
|
Compressor | Hitachi Industrial Equipment Systems | 0.75P-9.5VP5 | Unknown |
New and Used
|
Chiba Prefecture |
KA Machine Co., Ltd.
|
Details |